Specification lime improvement carried out to specified mix design dicated by client.
Volume of treated fill: 15,000m3
Lime stabilised capping layer for new units. Existing units surrounded area so dust monitoring essential.
Area of stabilisation: 24,000m2
Depth of stabilisation: 350mm
Cut and fill stabilisation of roads on new housing estate. High Sulphates in the soil required the use of GGBS (Gound Granulated Blast Furnace Slag).
Stabilisation of very poor soils, in layers, to form a piling platform and also lorry park and access road for a new warehouse development.